Hydraulic motor MR

Model – Spool valve, roller rotor
Flange mounting
Motor with needle bearing
Side and rear ports
Shafts – straight, splined and tapered
High and low pressure shaft seal
Metric and BSPP ports
Speed sensor
Other special features
Fluid under pressure | Mineral-based – HLP (DIN 51524) or HM (ISO 6743/4) |
Temperature range | -40÷140 °C |
Optimal viscosity range mm2/s | 20÷75 |
Filtration | ISO code 20/16 (Minimum recommended liquid filtration of 25 microns) |
Code | Volume | Max speed | Max Torque | Power | Debit | ||||
[cm3/rev] | [RPM] | [daNm] | [kW] | [Ipm] | |||||
cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
MR 50 | 51,5 | 775 | 970 | 10 | 13 | 7 | 8,5 | 40 | 50 |
MR 80 | 80,3 | 750 | 940 | 20 | 22 | 12,5 | 15 | 60 | 75 |
MR 100 | 99,8 | 600 | 750 | 24 | 28 | 13 | 15 | 60 | 75 |
MR 125 | 125,7 | 475 | 600 | 30 | 34 | 12,5 | 14,5 | 60 | 75 |
MR 160 | 159,6 | 375 | 470 | 39 | 43 | 11,5 | 14 | 60 | 75 |
MR 200 | 199,8 | 300 | 375 | 38,5 | 46 | 9 | 12 | 60 | 75 |
MR 250 | 250,1 | 240 | 300 | 39 | 47 | 8 | 9,5 | 60 | 75 |
MR 315 | 315,7 | 190 | 240 | 36 | 47 | 5 | 8 | 60 | 75 |
MR 400 | 397 | 150 | 190 | 38 | 47 | 4,8 | 6,8 | 60 | 75 |
* Intermittent operation: permissible values may occur for a maximum of 10% of each minute.